ASHRAE 62.1-2022: Essential Guide to Indoor Air Quality & Ventilation Standards

Sale!
US$140.00 US$39.99

Optimize indoor air quality and ventilation systems with the latest ASHRAE Standard 62.1-2022. This ANSI-approved guide is crucial for HVAC engineers, building managers, and indoor environmental quality professionals. Ensure compliance and create healthier indoor spaces with:

Key Features:

  • Updated ventilation rate calculations for various building types
  • Latest guidelines on air cleaning and filtration technologies
  • Comprehensive indoor air quality procedures and monitoring methods
  • Enhanced requirements for natural ventilation systems
  • Revised standards for demand-controlled ventilation
  • Updated guidance on outdoor air quality assessment

Benefits:

  • Improve occupant health, comfort, and productivity
  • Reduce energy consumption while maintaining air quality
  • Ensure compliance with current building codes and regulations
  • Implement cutting-edge ventilation strategies
  • Address emerging indoor air quality challenges

Stay at the forefront of indoor environmental quality management with ASHRAE 62.1-2022. Whether you're designing new buildings or upgrading existing systems, this standard is your essential resource for creating safe, comfortable, and energy-efficient indoor environments. Order now to breathe new life into your ventilation and air quality practices.

 

Product Details

Published: 2022

ANSI Approved

Number of Pages: 86

Units of Measure: Dual

File Size: 1 file , 1.7 MB

Product Code(s): D-86308, 86308

Note: This product is unavailable in Russia, Belarus

Frequently Asked Questions:

ASHRAE 62.1-2022


What is ASHRAE Standard 62.1-2022?

ASHRAE Standard 62.1-2022 is the latest edition of guidelines for ventilation and acceptable indoor air quality in commercial and institutional buildings. It provides methods for determining ventilation rates and other measures to maintain good indoor air quality

What are the main procedures outlined in ASHRAE 62.1-2022?

The standard outlines three main procedures for calculating mechanical ventilation rates: the Natural Ventilation Procedure (NVP), the Ventilation Rate Procedure (VRP), and the Indoor Air Quality Procedure (IAQP)

What are the major updates in the 2022 edition?

Key updates include changes to the Indoor Air Quality Procedure (IAQP), new requirements for natural ventilation in non-attainment zones, and the removal of non-transient residential units from the scope

How does the Indoor Air Quality Procedure (IAQP) differ from the Ventilation Rate Procedure (VRP)?

The IAQP is a performance-based approach that allows for various methods to achieve contaminant concentration limits, including source control and air cleaning. The VRP is a prescriptive approach using predetermined outdoor air intake rates for different space types

What are the benefits of using the IAQP?

The IAQP can lead to reduced ventilation rates, lower energy consumption, and potentially lower capital costs while maintaining acceptable indoor air quality

How does ASHRAE 62.1-2022 address air cleaning technologies?

The standard now specifies test methods for verifying the efficiency of air cleaning systems, such as ASHRAE Standard 145.2 for gas-phase air cleaning systems

What are the new verification requirements in ASHRAE 62.1-2022?

The standard now requires objective IAQ verification post-occupancy and a subjective verification where at least 80% of occupants must be satisfied with the IAQ as measured by a survey

How does ASHRAE 62.1-2022 impact LEED certification?

The updates in ASHRAE 62.1-2022 can positively impact LEED certification, particularly in areas related to minimum indoor air quality performance and energy optimization

What tools are available to help with ASHRAE 62.1-2022 compliance?

ASHRAE has released a calculator for mass balance equations used with the revised Indoor Air Quality Procedure, available for purchase

Is compliance with ASHRAE 62.1-2022 mandatory?

While not mandatory, compliance with ASHRAE 62.1-2022 is highly recommended to ensure good indoor air quality, promote occupant health and comfort, and potentially reduce liability risks

How does ASHRAE 62.1-2022 define acceptable indoor air quality?

The standard provides specific definitions of acceptable IAQ for various space types, listing 14 design compounds, mixtures, and PM2.5 that must remain below specified limits

How often is ASHRAE Standard 62.1 updated?

ASHRAE typically reviews and updates its standards every three years, with the possibility of addenda and errata issued between major revisions

How does ASHRAE 62.1-2022 address ventilation in healthcare facilities?

While ASHRAE 62.1-2022 provides general guidelines, healthcare facilities should primarily refer to ASHRAE Standard 170 for specific ventilation requirements in healthcare settings.

What are the minimum ventilation rates specified in ASHRAE 62.1-2022?

The standard provides tables with minimum ventilation rates for various space types, based on both occupancy and floor area. These rates are typically expressed in cubic feet per minute (cfm) per person and cfm per square foot.

How does ASHRAE 62.1-2022 handle demand-controlled ventilation (DCV)?

The standard provides guidelines for implementing DCV systems, including CO2-based control strategies and occupancy sensors, to adjust ventilation rates based on actual occupancy.

What are the requirements for natural ventilation in ASHRAE 62.1-2022?

The standard outlines specific criteria for natural ventilation, including minimum openable areas, location of openings, and control requirements. It also addresses limitations in areas with poor outdoor air quality.

How does ASHRAE 62.1-2022 address air filtration requirements?

The standard specifies minimum efficiency reporting value (MERV) ratings for air filters based on particle size efficiency. It also provides guidance on filter installation and maintenance.

What are the ventilation requirements for parking garages in ASHRAE 62.1-2022?

The standard provides specific ventilation rates for enclosed parking garages, including requirements for CO monitoring and ventilation system activation based on contaminant levels.

How does ASHRAE 62.1-2022 address ventilation in multi-family residential buildings?

While the standard primarily focuses on commercial and institutional buildings, it does provide some guidance for common areas in multi-family residential buildings. For individual dwelling units, ASHRAE Standard 62.2 should be consulted.

What are the requirements for exhaust systems in ASHRAE 62.1-2022?

The standard provides guidelines for exhaust systems in various space types, including kitchens, bathrooms, and laboratories. It specifies minimum exhaust rates and addresses issues such as makeup air and exhaust location.

How does ASHRAE 62.1-2022 address indoor air quality during construction and renovation?

The standard includes provisions for protecting HVAC systems during construction and renovation, as well as guidelines for flushing out buildings before occupancy to remove contaminants.

What are the documentation requirements specified in ASHRAE 62.1-2022?

The standard requires documentation of the ventilation system design, including calculations, assumptions, and operational parameters. This documentation is crucial for commissioning, operation, and maintenance of the ventilation system.

How does ASHRAE 62.1-2022 address the issue of outdoor air quality?

The standard provides guidance on assessing outdoor air quality and its impact on ventilation system design. It includes provisions for air cleaning when outdoor air quality does not meet specified criteria.

What are the requirements for air classification in ASHRAE 62.1-2022?

The standard classifies air into four categories based on contaminant concentration, bioaerosol concentration, and odor intensity. These classifications determine the suitability of air for recirculation or transfer to other spaces.

How does ASHRAE 62.1-2022 address ventilation in spaces with high occupant density?

The standard provides specific guidance for spaces with high occupant density, such as auditoriums and meeting rooms, including provisions for increased ventilation rates and considerations for intermittent occupancy.

What are the requirements for monitoring and maintaining indoor air quality in ASHRAE 62.1-2022?

The standard outlines requirements for monitoring key indoor air quality parameters, including CO2 levels in some cases. It also provides guidance on maintenance procedures to ensure ongoing compliance with indoor air quality standards.